Here is a step by step example of how to fill out an FMEA template:

Step
Example
Identify each Part or Process Step Preparation for an MRI-magnetic resonance imaging-in a hospital
Identify Potential Failure Modes - All of the manners in which the part or process could fail.

Cracked, loosened, deformed, leaking, oxidized, overlooked, etc.

For example, MRIs produce intense magnetic fields. One patient was killed by a flying fire extinguisher pulled off the wall by the MRI.

Identify any Potential Effect(s) of Failure - Consequences on other systems, parts, or people.

Noise, unstable, inoperative, impaired, injury, death, etc.

The consequence of a fire extinguisher getting pulled off of the wall is that it could hit someone.

Rank Severity of the Effect (1-10)

1 = none or no effect, 10 = "hazardous without warning"

For example: a tire blow out may be rated a 2 while a a fire extinguisher to the skull would be rated a 10.

Evaluate Potential Cause(s) / Mechanism(s) of Failure List every potential cause and/or failure mechanism such as Incorrect material, improper maintenance, fatigue, wear, etc.
Rank the Possibility of Occurrence (1-10) 1 would be remote while a 10 would be high
List Your Current Design Controls. List prevention and detection activities to assure design adequacy and prevent or reduce occurrence.
Rank Your Ability to Detect a Failure Using these Controls (1-10) 1 is almost certain to 10 absolute uncertainty.
Calculate the risk-priority number (RPN) for each part or step. RPN = severity * occurrence * detection.
Design Recommended Improvement Action(s) Design additional actions to reduce severity, occurrence and detection ratings. Severity of 9 or 10 requires special attention.
Assign Responsibility & Target Completion Date for implementing designed improvements.  
Monitor Actions Taken and effects on RPN.  

FMEA

FMEA Template

The FMEA template is just one of the tools included in the QI Macros for Excel SPC Software.

Download the FREE 30-day Evaluation copy of the QI Macros Excel SPC Software for Six Sigma

QI Macros - Download with backup CD & User Guide (#230) $139 + S&H
QI Macros - Download Only - No Shipping or Customs Duties (#W230) $139

 

 

Download
FREE
30-Day Trial



QI Macros SPC Software for Excel

Or Buy It Now
for only $139!
Unconditional
90-Day
Money-Back
Guarantee

Add QI Macros Starter Kit - SPC Software plus training CD and tools book (#275) $197 plus S&H
Add SPC Simplified System - SPC Simplified Book and DVD, Plus SPC Software, Training Cd and Tools Example Book (#285) $297 plus S&H


 
home | products | services | search | sitemap | view cart | contact