AIAG Gage R&R
Measurement System Analysis (MSA) involves Gage R&R
(repeatability and reproducibility) studies to evaluate your measurement
systems.
When I first got involved with quality, I learned about the "five
M's" that constituted most root causes: man, machine, materials,
methods, and measurement.
Because I worked in a predominantly service industry, I couldn't quite
grasp how measurement could be a common cause of variation. But, if you
work in manufacturing, you know that gages and how they are used
can be a key cause of variation.
Measurement Systems Analysis (MSA)
MSA is actually quite simple, but even seasoned SPC veterans don't
seem to understand it. So I thought I'd simplify it for you.
First, Gage R&R studies are usually performed on variable
data - height, length, width, diameter, weight, viscosity, etc.
Second, when you manufacture products, you want to monitor the
output of your machines to make sure that they are producing products
that meet the customer's specifications. This means that you have to measure
samples coming off the line to determine if they are meeting your customer's
requirements.
Third, when you measure, three factors come into play:
- Part variation (differences between individual pieces manufactured)
- Appraiser variation (a.k.a., reproducibility) -
Can two different people get the same measurement using the same gage?
- Equipment variation (a.k.a., repeatability) -
Can the same person get the same measurement using the same gage
on the same part in two or more trials?
You want most of the variation to be between the parts, and less than
10% of the variation to be caused by the appraisers and equipment. Makes
sense, doesn't it? If the appraiser can't get the same measurement twice,
or two appraisers can't get the same measurement, then your measurement
system becomes a key source of error.
Conducting a Gage R&R Study
To conduct a Gage R&R study, you will need:
- five to ten parts from one batch or lot (# each part)
- two appraisers (people who measure the parts)
- one measurement tool or gage
- and a minimum of two measurement trials, on each part, by each appraiser
- a Gage R&R tool like the Gage R&R excel template
in the QI Macros.
The Gage R&R template can be purchased
separately or as part of the QI Macros
for Excel SPC Software.
Order Gage R&R Template
Gage RR Templates - $99 Download Only
Order the QI Macros for Excel SPC Software which includes the Gage R&R
template.
QI Macros Excel SPC Software for Histograms and Control Charts $139 Plus S&H
QI Macros for Excel Gage R&R Template
Here are samples of the Gage R&R template input sheet and
results sections using sample data from the AIAG Measurement Systems Analysis
Third Edition.


Gage R&R System Acceptability
- % R&R<10% - Gage System Okay
(Most variation caused by parts, not people or equipment)
- % R&R<30% - May be acceptable based on importance of application
and cost of gage or repair
- % R&R>30% - Gage system needs improvement
(People and equipment cause over 1/3 of variation)
What To Look For
Repeatability: Percent Equipment Variation
(%EV - Can the same person using the same gage measure the same
thing consistently)
If you simply look at the measurements, can each appraiser get the same
result on the same part consistently, or is there too much variation?
Example (looking at measurements from one appraiser only):
- No Equipment Variation: (Part 1: 0.65, 0.65; Part 2: 0.66, 0.66)
- Equipment Variation: (Part 1: 0.65, 0.67; Part 2: 0.67, 0.65)
If repeatability (Equipment variation) is larger than reproducibility
(appraiser variation), reasons include:
- Gage needs maintenance (gages can get corroded)
- Gage needs to be redesigned to be used more accurately
- Clamping of the part or gage, or where it's measured needs
to be improved (imagine measuring a baseball bat at various places along
the tapered contour; you'll get different results.)
- Excessive within-part variation (Imagine a steel rod that's bigger
at one end than the other. If you measure different ends each time,
you'll get widely varying results.)
Reproducibility: Percent Appraiser Variation
(% AV-can two appraisers measure the same thing and get the same answer?)
Example (looking at measurements of the same part by two
appraisers):
- No Appraiser Variation: (Appraiser 1, Part 1: 0.65, 0.65; Appraiser
2, Part 1: 0.65, 0.65)
- Appraiser Variation: (Appraiser 1, Part 1: 0.65, 0.65; Appraiser 2,
Part 1: 0.66, 0.66)
If you look at the line graph of appraiser performance, you'll be able
to tell if one person over reads or under reads the measurement.
If reproducibility (appraiser variation) is larger than repeatability
(equipment variation), reasons include:
- Operators need to be better trained in a consistent method for using
and reading the gage
- Calibrations on gage are unclear
- Fixture required to help the operator use gage more consistently
Mistakes People Make
Many people call us because they don't like the answer they get using
the Gage R&R template. Most of the time, it's because they
didn't follow the instructions for conducting the study. Here are some
of the common mistakes I've seen:
- Forgetting that the Gage R&R study is evaluating their measurement
system and NOT their products. Gage R&R does not care about how
good your products are. It only cares about how good you measure your
products.
- Using only one part. If you only use one part, THERE CAN'T BE ANY
PART VARIATION, so people and equipment are the ONLY source of variation.
- Using the one part measurement for all 10 parts (again, there won't
be any part variation, so it all falls on the people and equipment).
- Using too many trials (if you use five trials, you have more opportunity
for equipment variation).
- Using too many appraisers (if you use all three, you have more opportunity
for appraiser variation).
- Using fake data. Try using the AIAG SPC data the QI Macros loads on
your computer at c:\qimacros\testdata.
- Using a gage that measures in too much detail. If your part is 74mm
+/- 0.05, then you don’t need a gage that measures to a thousandth of
an inch (0.001) you only need one that measures to the hundredth of
an inch (0.01).
Challenges You Will Face
One customer faced an unusual challenge: they were producing parts so
precisely that there was little or no part variation even when measured
down to 1/10,000th of an inch. Their existing gages ceased to detect
any variation from part to part.
As your process improves and your product approaches the ideal target
measurement, you'll have less part variation and more chance
for your equipment or people to become the major source of variation.
As your product and your process improve, your measurement system will
need to improve as well.
Conclusion
Your goal is to minimize the amount of variation and error introduced
by measurement, so that you can focus on part variation. This, of course,
leads you back into the other root causes of variation: process, machines,
and materials.
If you manufacture anything, measurement system analysis can help you
improve the quality of your products, get more business from big customers,
and baffle your competition. Enjoy.
For more information select one of the following articles:
Gage R&R Bias and Linearity
Gage R&R Destructive
Testing
Gage R&R Software
Obviously, crunching all of the numbers for a Gage R&R study is non-trivial,
but you can do it easily with the Gage R&R template for Excel. Buy
one separately or as part of the QI
Macros for Excel SPC Software.
Order Gage R&R Template
Gage RR Templates - $99 Download Only
Order the QI Macros for Excel SPC Software which includes the Gage R&R
Template.
QI Macros Excel SPC Software for Histograms and Control Charts $139 Plus S&H
© 2007 KnowWare International Inc. (888) 468-1537
knowwareman@qimacros.com
Home
| Lean Six Sigma
| QI Macros
| KnowWare
| Site Map
|
Download
FREE
30-Day Trial

This is one of 19 SPC charts and over 70 templates included with the QI Macros
for Excel SPC Software $139. Just select the data you want graphed and in just
seconds the QI Macros will draw the graph and do all the math for you.
The QI Macros draws line, pie, bar, pareto, box whisker, histogram (Cp, Cpk),
scatter and control charts (with stability analysis).
Templates include the Ishikawa diagram, QFD, DOE, FMEA, PPAP, and Gage R&R
for MSA. Performs ANOVA, t-test, F-test, and regression analysis.
Measurement System Analysis Gage R&R Whitepaper, 25 pages, $20
To get formulas and a fuller understanding, order the MSA reference from
the AIAG:
www.aiag.org
For a complete listing of AIAG books, go to:
aiag/publications
Keyboard Wedges & Gage Interfaces

WedgeLink keyboard
wedges for transferring gage data directly into Excel
|